Explanation of a Common Point Ground
How to Ground ESD Mat with Common Point Ground
How to Ground Anti Static Mat with Common Point Ground

Anti Static Work Mats

Anti Static Rubber Work Mats are installed with (2) two snaps on the corners to connect a common point ground for an ESD wrist strap.

SizesQty 1-9Qty 10+
2' x 3'$55.60 USD$44.88 USD
2' x 4'$68.30 USD$54.64 USD
2' x 5'$81.00 USD$64.80 USD
2' x 6'$93.70 USD$74.96 USD
30" x 5' (Blue)$96.88 USD$77.50 USD
30" x 5' (Dark Blue, Gray, Green)$115.67 USD$101.97 USD

Specs

► Meets ANSI / ESD STM 4.1 Standard

► Lead-Free. Recyclable. Meets European Union (EU) Restriction of Hazardous Substances Directive (RoHS) regulating the reuse of products used in electrical and electronic equipment.

PropertiesUnitsTypical aluesTest Method
Material-Nitrile Butadiene Rubber / Carbon-
ThicknessInches.08ASTM D-2103
ThicknessMillimetres2ASTM D-2103
Tensile Strength • Top Layerkg / sq. cm> 120ASTM D-412
Tensile Strength • Bottom Layerkg / sq. cm> 160ASTM D-412
Tear Strength • Top Layerkg / sq. cm> 90ASTM D-412
Tear Strength • Bottom Layerkg / sq. cm> 100ASTM D-412
Elongation • Top Layer%350ASTM D-412
Elongation • Bottom Layer%250ASTM D-412
Hardness • Top LayerShore A50ASTM D-2240
Hardness • Bottom LayerShore A60ASTM D-2240
Gravity • Top Layer-1.3ASTM D-792
Gravity • Bottom Layer-1.4ASTM D-792
ESD Surface Resistance • Top Layerohms / square< 109ASTM D-257
ESD Surface Resistance • Bottom Layerohms / square< 105ASTM D-257
Volume Resistivity • Top Layerohms / square< 108ASTM D-257
Volume Resistivity • Bottom Layerohms / square< 104ASTM D-257
Static Decayseconds< 0.01EIA-541
Temperature ToleranceFahrenheit / Celsius187F / 86C-

ANSI / ESD S4.1 Test Data

The linked ANSI/ESD STM4.1 qualification report measures resistance to a groundable point (Rgp) and point-to-point resistance (Rpp) at 12% and 48% relative humidity, at 68°F (20°C). It reports three specimens and 27 readings per humidity condition.

5300 Series S4.1 overview: all 54 readings below the report's 1 gigaohm limit, with separate Rgp and Rpp ranges at 12% and 48% relative humidity

All 54 readings are below the report’s stated limit of 1 × 109 Ω (1 GΩ) for both measurement types. The charts summarize the detailed measurement table in the linked report. Values are resistance in ohms; 1 MΩ is one million ohms.

Low relative humidity: 12% RH

5300 Series at 12% relative humidity: overall resistance 7.93 to 31.6 megaohms; Rgp 7.93 to 17.7 megaohms and Rpp 18.4 to 31.6 megaohms

The lowest recorded resistance is 7.93 × 106 Ω and the highest is 3.16 × 107 Ω (7.93–31.6 MΩ). Rgp readings range from 7.93 to 17.7 MΩ; Rpp readings range from 18.4 to 31.6 MΩ.

Moderate relative humidity: 48% RH

5300 Series at 48% relative humidity: overall resistance 8.17 to 28.1 megaohms; Rgp 8.17 to 15.1 megaohms and Rpp 17.4 to 28.1 megaohms

The lowest recorded resistance is 8.17 × 106 Ω and the highest is 2.81 × 107 Ω (8.17–28.1 MΩ). Rgp readings range from 8.17 to 15.1 MΩ; Rpp readings range from 17.4 to 28.1 MΩ.